Frequently Asked Questions
General
No. Fall Safe products, including those sold under the Reliance name, don't have a fixed 5-year service life or expiration date. Whether a product stays in service depends on its condition, not its age. Inspect it before each use, have a competent person inspect it at least once a year, and remove it from service immediately if it shows damage, wear or deterioration, or if it has arrested a fall.
No. Reliance products, now part of the Fall Safe line, don't have an expiration date. Inspect equipment before each use, and remove anything that's damaged, worn or has arrested a fall. A competent person should also inspect equipment at least once a year.
Yes. You can mark fall protection equipment with a permanent felt-tip marker, such as a Sharpie. Don't use paint or solvent-based markers, which can damage the webbing, and don't write over or cover product labels. Where possible, mark an area of the webbing that doesn't bear load.
Most Fall Safe products are made in Deer Park, Texas, and SureWerx is moving more production there. Check each product's specifications for its country of origin.
Fall Safe designs fall protection around a simple idea: PPE should support the work, not get in the way of it. The brand calls this Performance Protection. Products are developed to solve problems workers report on the job, such as nuisance lock-ups, restricted movement and uncomfortable gear, while meeting OSHA and ANSI requirements.
It depends on the industry. In construction, OSHA requires fall protection when workers are exposed to a fall of 6 ft or more to a lower level (29 CFR 1926.501(b)(1)). In general industry, the trigger height is 4 ft (29 CFR 1910.28(b)(1)). Protection can include guardrails, safety nets or personal fall arrest systems. Work above dangerous equipment can require fall protection at any height.
No. Only connect to an anchorage that's approved for fall protection. OSHA requires an anchorage for personal fall arrest to support at least 5,000 lb per attached worker, or to be designed and installed as part of a complete system with a safety factor of at least two, under the supervision of a qualified person (29 CFR 1926.502(d)(15); 1910.140(c)(13)). Pipes, conduit, handrails and ductwork often can't meet that requirement and may fail in a fall. When in doubt, use a rated anchorage connector.
Yes. OSHA's fall protection rules don't include an exception for short tasks. If a worker is exposed to a fall at or above the trigger height (6 ft in construction, 4 ft in general industry), fall protection is required, however quickly the job can be done.
No. A ladder is a way to reach a work area, not a fall protection system. Workers still need to follow ladder safety rules. In general industry, fixed ladders that extend more than 24 ft above a lower level need a ladder safety system or personal fall arrest system, with existing ladders phased in by November 2036 (29 CFR 1910.28(b)(9)). A vertical ladder safety system is one way to meet this requirement.
Full Body Harnesses
Use the sizing chart on each harness's product page, which matches size to the worker's height and weight. Allow for clothing worn under the harness: if a worker is between sizes or wears bulky layers such as winter gear, size up. Once it's on, adjust the harness for a snug fit, following the fitting steps in the user instructions.
Fall Safe offers several harness lines at different price points and feature levels, including the A Series, Flex and Construction Comfort lines. Compare them by the type of work, how long workers wear the harness each day, and the features your crew needs, such as padding, tool loops or extra D-rings.
Inspect a harness before every use for cuts, burns, frayed or worn webbing, broken stitching, damaged or missing labels and defective hardware (29 CFR 1926.502(d)(21); 1910.140(c)(18)). ANSI Z359.2 also calls for a competent person to inspect it at least once a year, or more often if the manufacturer or employer requires. Remove any harness that fails inspection or has arrested a fall from service immediately.
The Flex harness lets the webbing move forward and back as the worker bends, reaches and climbs. It's designed to keep the harness comfortable through a full range of motion.
Yes. Flex harnesses adjust to fit women properly, and Fall Safe provides sizing charts specifically for women. The Flex hip design also helps the harness stay comfortable on workers of different body shapes and sizes.
Fall Safe harnesses don't have an expiration date. Replace a harness when it fails inspection, for example if it shows cuts, burns, worn webbing, broken stitching, damaged hardware or missing labels, or if it has been involved in a fall. Inspect it before each use, and have a competent person inspect it at least once a year.
Self-Retracting Devices
No, Fall Safe doesn't recommend it. With a D-ring extender, the SRL's energy absorber sits away from the worker's back, where it can strike the edge in a fall and may cause the lifeline to separate. Connect leading-edge SRLs directly to the dorsal D-ring as shown in the user instructions. See the Fall Safe technical bulletin on D-ring extenders for details.
Yes, but only an ANSI Z359.14 Class 2 personal SRL. Class 1 SRLs aren't approved for use in a MEWP, because they're designed for anchorage at or above the dorsal D-ring. When the MEWP is traveling or being repositioned, Fall Safe recommends a restraint lanyard, such as part 717505, instead.
Yes. Fall Safe SRLs are tested to ANSI Z359.14 requirements, which cover performance at temperatures from -40°F to 130°F. In freezing conditions, check the lifeline and housing for ice before each use, since ice can affect retraction and locking.
The Micro-Loc and Skyloc II ANSI Z359.14 Class 1 models are rated for a maximum capacity of 400 lb, including the worker's clothing, tools and equipment. Most fall protection equipment is rated for 130 to 310 lb, so check that every part of the system, including the harness, anchorage connector and anchorage, is also rated for the heavier load.
It depends on where the device is anchored and how far the worker moves from it. As a guide, Fall Safe Class 2 leading-edge devices need as little as 4 ft of clearance when anchored overhead, about 11 ft when anchored at foot level with no swing, and up to about 20 ft when the worker is offset to the side and a swing fall is possible. Calculate clearance before starting work, set up the anchorage to minimize swing falls, and use the clearance chart in each product's user instructions.
The Skyloc II is a self-retracting lifeline for fall arrest when working at height. It's lightweight and portable, so it's easy to move between jobs and work areas. A leading-edge version (Skyloc II LE) is available for work near unprotected edges.
The Skyloc II is used in construction, maintenance and other industries where workers need fall arrest at height. The leading-edge version (Skyloc II LE) is designed for work near unprotected edges. Check each model's ANSI class before use: Class 1 for anchorage at or above the dorsal D-ring, Class 2 for leading edges and anchorage below it.
Skyloc II Class 2 models use a 7/32 in galvanized steel cable lifeline, and Class 1 models use 3/16 in galvanized steel cable. Some configurations, such as the Wildcat, use stainless steel cable or Dyneema rope instead. Check each model's specifications for its lifeline type.
The FT-R's swiveling anchor and leg-end connectors make the device easier to install and keep the lifeline from twisting as the worker moves.
The Skyloc II meets OSHA 29 CFR 1926.502 (construction) and 1910.140 (general industry) and ANSI/ASSP Z359.14-2021. See each model's label and Declaration of Conformity for its ANSI class.
Anchorage Connectors
An anchorage connector is the device that links a connecting device, such as a shock-absorbing lanyard or self-retracting lifeline (SRL), to an anchorage: the beam, column, roof or other structure that holds the load if a worker falls. Common examples include web and cable slings, I-beam clamps and trolleys, and fixed anchors that are bolted, welded or set into concrete. The anchorage connector is one part of a complete personal fall arrest system, along with a full body harness and a connecting device. Every component must be compatible with the others and rated for the work being done.
Under OSHA, an anchorage used for personal fall arrest must support at least 5,000 lb for each worker attached, or be designed, installed and used as part of a complete system with a safety factor of at least two, under the supervision of a qualified person (29 CFR 1926.502(d)(15) for construction and 1910.140(c)(13) for general industry). In construction, anchorages for positioning systems must support at least 3,000 lb or twice the potential impact load, whichever is greater (29 CFR 1926.502(e)(2)). Both the anchorage connector and the structure it's attached to must meet the requirement. Check the rating on the product label, and have a qualified person confirm the structure.
Start with the structure you're tying off to and whether the anchor needs to stay in place:
Anchor slings (web or cable) wrap around beams, columns and other structural members. They're portable and easy to move between jobs.
I-beam anchors clamp onto a steel beam flange. Trolley and slider styles let the worker travel along the beam. Check the anchor's flange width range against your beam before ordering.
Fixed steel anchors are bolted, welded or pushed through a structure to create a permanent tie-off point.
Concrete anchors are set into concrete to create an anchor point that stays in place.
Remote-connect systems let you attach an anchor to an overhead beam or receiver from the ground with a pole, before anyone is exposed to a fall.
For permanent installations, have a qualified person confirm the structure can carry the load.
Only if both the anchorage connector and the structure are rated for more than one user. OSHA requires an anchorage to support 5,000 lb for each attached worker, so an anchor shared by two workers generally needs to support 10,000 lb, unless a qualified person has engineered the system with a safety factor of at least two (29 CFR 1926.502(d)(15)). Many slings and beam anchors are rated for a single user, while some overhead beam grips and concrete anchor systems are rated for two. Check the product label and user instructions for the number of users allowed. Never attach a second worker to an anchor rated for one.
OSHA sets the legal requirements for fall protection anchorages in the US. ANSI/ASSP Z359.18-2017 is the voluntary consensus standard for anchorage connectors used in active fall protection. It adds dynamic strength, residual strength, serviceability and corrosion testing, and it replaced the anchorage connector requirements in the older ANSI Z359.1-2007. The standard isn't retroactive, so connectors marked to Z359.1-2007 can remain in service. OSHA doesn't require ANSI compliance, but many employers, owners and job specifications do. Check the product label and Declaration of Conformity for the standards each anchorage connector meets.
Inspect anchorage connectors before each use for wear, cuts, corrosion, deformation, missing labels and other damage, and remove any defective connector from service (29 CFR 1926.502(d)(21) and 1910.140(c)(18)). ANSI Z359.2 also calls for a competent person to inspect fall protection equipment at least once a year, or more often if the manufacturer requires it. An anchorage connector that has arrested a fall must be removed from service immediately and can't be used again until a competent person confirms it's undamaged and suitable for reuse. Some web slings use wear-indicator webbing designed to make worn areas easier to spot during inspection.
No. At a junction where two horizontal I-beams cross, a fall could load the beam slider sideways (cross-loading), which it isn't designed to handle. Use a beam slider only along a straight run of a single beam within its rated flange width range, and follow the user instructions for installation.
Lanyards
A shock-absorbing (energy-absorbing) lanyard is a fixed-length connector, usually 6 ft or shorter, with an energy absorber that deploys during a fall to reduce the force on the worker. A self-retracting lifeline (SRL) extends and retracts as the worker moves, then locks quickly when a fall begins. Because an SRL takes up slack, an overhead SRL usually limits free fall and needs less clearance below the work area. Lanyards are lighter and simpler, and work well where there's enough clearance and the worker stays near the anchor. Shock-absorbing lanyards are covered by ANSI Z359.13 and SRLs by ANSI Z359.14.
With a 6 ft shock-absorbing lanyard anchored at dorsal D-ring height, plan for about 18 to 19 ft of clearance between the anchor and the nearest obstruction below.
A typical calculation adds:
6 ft of lanyard length (free fall)
Up to 4 ft of deceleration distance as the energy absorber deploys
About 1 ft of harness stretch and D-ring shift
About 5 ft from the D-ring to the bottom of the worker's feet
A safety margin, commonly 2 to 3 ft
Always use the clearance figures in the product's user instructions. Anchoring below the D-ring, swing falls and heavier workers all increase the clearance needed. Where clearance is limited, consider an SRL.
Both keep a worker in place, but they do different jobs.
A positioning lanyard holds the worker at the work location so both hands are free, for example while leaning back against a wall, column or rebar mat. It's typically attached to the harness's side D-rings. OSHA construction rules limit free fall in a positioning system to 2 ft and require an anchorage of at least 3,000 lb or twice the potential impact load (29 CFR 1926.502(e)).
A restraint lanyard is set to a length that stops the worker from reaching an unprotected edge or opening, so a fall can't happen in the first place.
Positioning lanyards are covered by ANSI Z359.3.
No. Most positioning and restraint lanyards have no energy absorber, so they can't safely stop a free fall beyond what they're designed for. A fall onto one could exceed OSHA's 1,800 lb maximum arresting force for a worker in a full body harness (29 CFR 1926.502(d)(16)(ii)). Wherever a fall is possible, the worker needs a personal fall arrest system with a shock-absorbing lanyard or SRL. Positioning work is often paired with a separate fall arrest connection as a backup. The reverse is usually acceptable: a shock-absorbing lanyard can generally be used for restraint, if its user instructions allow it.
Use a twin-leg (Y-style) lanyard when a worker needs to move between anchor points without ever being disconnected. The worker clips the free leg to the next anchor before unclipping the first, which is what "100% tie-off" means. Twin-leg lanyards are common in steel erection, rebar work and scaffolding. A twin-leg lanyard is for one worker only. Store the unused leg only where the user instructions allow, usually a lanyard keeper on the harness, and don't clip it to the back D-ring. Only wrap a lanyard around a structure and clip it back to itself (tie-back) if it's designed and labeled for tie-back use.
Inspect lanyards before each use for cut, frayed, burned or discolored webbing, broken stitching, damaged or corroded hooks, missing labels and any sign the energy absorber has deployed. Remove damaged lanyards from service (29 CFR 1926.502(d)(21)). ANSI Z359.2 also calls for a competent person to inspect equipment at least once a year, or more often if the manufacturer requires it. Fall Safe lanyards don't have an expiration date: whether a lanyard stays in service depends on its condition, not its age. A lanyard that has arrested a fall must be removed from service immediately (29 CFR 1926.502(d)(19)).
No. Fall Safe shock-absorbing lanyards and SRLs have a minimum capacity of 130 lb. Energy absorbers are designed to deploy within a rated weight range. A worker who weighs less may not generate enough force to deploy the absorber as designed, so the fall stops more abruptly and the forces on the body can exceed safe limits. Check each product's label for its rated capacity, which includes the worker's weight plus clothing, tools and equipment.
Generally yes, if the components are compatible. Connectors such as snap hooks and carabiners should meet ANSI Z359.12, which requires gates rated to 3,600 lb, and each component must be used within its own rating and instructions. A competent person should confirm that mixed components are compatible before use. Check the user instructions from both manufacturers, since some restrict mixing.
Systems
Up to 4 workers, depending on the system's span and the connecting devices used. Some configurations are limited to 2. Check the Skyline technical bulletins or contact Fall Safe technical services to confirm the capacity for your layout.
Yes. Skyline horizontal lifelines should be installed by trained personnel, and Fall Safe offers Skyline training classes. OSHA also requires horizontal lifelines to be designed, installed and used under the supervision of a qualified person, as part of a complete system with a safety factor of at least two (29 CFR 1926.502(d)(8)).
At least once a year, by a competent person trained in Skyline inspection. Users should also inspect the system before each use. Any system that has arrested a fall must be removed from service until a competent person inspects it.
At least once a year, by a competent person trained in ARFAS rigid rail inspection. Users should also inspect the system before each use. Any system that has arrested a fall must be removed from service until a competent person inspects it.
A rigid rail doesn't deflect in a fall, so the fall clearance you need depends mainly on the connecting device, such as an SRL. A cable horizontal lifeline sags under load, which usually adds to the clearance required. That makes rigid rails a good fit where clearance below the work area is limited.
The ARFAS is built from a small set of simple components, which allows a wide range of mounting options. Multiple rails can be connected to cover larger work areas, and its lightweight design is intended to make installation faster and less costly.
When the ARFAS is installed overhead and paired with a Fall Safe FLO or Skyloc II SRL, arrest distances can be less than 24 in. The system is designed for permanent installation indoors or outdoors in a wide range of environments.
Rescue and Controlled Descent
OSHA requires employers to provide for the prompt rescue of workers after a fall, or to make sure workers can rescue themselves (29 CFR 1926.502(d)(20); 1910.140(c)(21)). In practice, meeting that requirement means having a rescue plan in place before work begins, one that identifies the equipment, procedures and trained rescuers you'll rely on.
OSHA doesn't set a maximum time, and there's no time that can be considered safe. Suspension trauma (orthostatic intolerance) can develop within minutes as blood pools in the legs, so a fallen worker needs to be rescued as quickly as possible. Suspension trauma straps can relieve pressure while the worker waits, but they don't replace a rescue plan.
An effective fall rescue plan identifies:
Rescue procedures for each work location
How to call for help and who to contact
The rescue equipment to be used
Trained rescuers and their responsibilities
Self-rescue options, where feasible
How the rescued worker will be treated and medically evaluated
The plan should be specific to the site and practiced regularly.
Start the site's rescue plan immediately. Bring the worker down as quickly as possible, because hanging in a harness can lead to suspension trauma (orthostatic intolerance), a serious medical condition. Don't rely on calling emergency services alone; they may not arrive in time or have the equipment to reach the worker. After rescue, have the worker evaluated by medical professionals.
Fall Safe suspension trauma straps come in a single pouch that attaches to the harness with a loop connection. After a fall, the worker deploys the straps and steps into them to take pressure off the legs while waiting for rescue.